Sign In | Join Free | My burrillandco.com
Home > Transformer Test Equipment >

Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test

    Buy cheap Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test from wholesalers
     
    Buy cheap Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test from wholesalers
    • Buy cheap Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test from wholesalers
    • Buy cheap Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test from wholesalers
    • Buy cheap Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test from wholesalers
    • Buy cheap Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test from wholesalers

    Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test

    Ask Lasest Price
    Brand Name : AI
    Model Number : TDT
    Certification : ISO
    Price : Negotiable
    Payment Terms : T/T, Western Union, L/C
    Supply Ability : 100000 sets per month
    Delivery Time : 15 days
    • Product Details
    • Company Profile

    Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test

    Transformer Tan Delta Test Equipment


    I.Introduction:

    TDT Tan Delta Test Equipment is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in;

    This Loss Angle Test Equipment can also supply high voltage source for testing.

    Frequency can be changed to 50Hz, 47.5Hz52.5Hz,45Hz55Hz, 60Hz, 57.5Hz62.5Hz, 55Hz65Hz; thus, this power factor tester can avoid interference of power frequency;

    This dissipation factor test equipment can also be used as power supply;



    II.Specifications:

    No.Item NameTransformer Tan Delta Test Loss Angle Test Dissipation Factor Test Equipment
    1Use conditions-15℃~40℃RH<80%
    2Anti-interferenceFrequency conversion
    3PowerAC 220V±10%Allowable generator
    4High output0.5KV~10KVEvery 0.1kV
    Precision2%
    Maximum current200mA
    Capacity2000VA
    5Self-excited powerAC 0V~50V/15A

    45HZ/55HZ 47.5HZ/52.5HZ

    55HZ/65HZ 57.5HZ/62.5HZ

    Automatic double frequency

    6Resolving powertgδ: 0.001%Cx: 0.001pF
    7Precisiontgδ:(Reading*1.0%+0.040%)
    Cx :(Reading*1.0%+1.00PF)
    8Measuring rangetgδUnlimited
    Cx15pF < Cx < 300nF
    10KVCx < 60 nF
    5KVCx < 150 nF
    1KVCx < 300 nF
    CVT testCx < 300 nF
    9CVT range10~10000
    accuracy0.1%
    Resolving power0.01
    10Dimension350*270*270mm
    11Memory sizeThe 200 group supports U disk data storage
    12Weight

    28 Kg


    Spares of Transformer Tan Delta Test Loss Angle Test Dissipation Factor Test Equipment


    Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test
    Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test
    NO.NameQuantityUnit
    1Main Unit1Set
    2Accessory case1PC
    3Red HV test cable1Root
    4Black LV test cable1Root
    5AC220V power cable1Root
    6

    CVT self-excited power cable (attached)


    1Root
    7

    Ground wire


    1Root
    8Fuse, printer paperSpare
    Quality Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test for sale